Girard RV Tankless Water Heater Error Code E2: False Flame Detected or Flame Sensor Circuit Fault
Girard Error E2 on RV Tankless Water Heater units (GSWH-2 (2GWHAM)) means False Flame Detected or Flame Sensor Circuit Fault. First check: Turn off the hot water faucet and shut off 12V DC power to the Girard water heater for 2 minutes to perform a hard board reset. Typical repair cost is $20-$65 DIY / $185+ Shop (Moderate (20-40 mins)).
What Does Girard Error E2 Mean?
On Girard RV Tankless Water Heater systems (GSWH-2 (2GWHAM)), Error E2 indicates False Flame Detected or Flame Sensor Circuit Fault. Review the most frequent root causes below before replacing hardware.
Most Common Causes
- Moisture, condensation, or soot bridging the flame sensor rod to ground
- Damaged or pinched flame-sense wire insulation touching the chassis
- Sticking gas valve leaving a residual pilot/flame after water shutoff
- Faulty flame-detection circuit on the Girard control board
How to Fix Girard Error E2 (Step-by-Step)
Recommended Replacement Part for Error E2
If basic checks and resets do not clear E2, verify your exact model sticker and check compatibility for the most commonly replaced part below:
Girard GSWH-2 Replacement Electrode & Flame Sensor Assembly