Independent RV diagnostic database. As an Amazon Associate we earn from qualifying purchases. Learn more · Safety Notice
Quick Answer

Girard Error E4 on RV Tankless Water Heater units (GSWH-2 (2GWHAM)) means Outlet Water Temperature Sensor Open or Shorted. First check: Turn off 12V power to the Girard water heater and open the exterior service door. Typical repair cost is $15-$35 DIY / $155+ Shop (Easy (15-30 mins)).

GSWH-2 (2GWHAM)
Low (Safe to DIY)
Easy (15-30 mins)
$15-$35 DIY / $155+ Shop
Safety First: Always turn off 120V/230V AC shore power, 12V/24V DC breakers, solar PV disconnects, and propane/LP gas valves before opening access panels or testing components. If you smell rotten eggs (propane), raw ammonia, or fuel leaks, evacuate immediately and call a certified RV technician.

What Does Girard Error E4 Mean?

On Girard RV Tankless Water Heater systems (GSWH-2 (2GWHAM)), Error E4 indicates Outlet Water Temperature Sensor Open or Shorted. Review the most frequent root causes below before replacing hardware.

Most Common Causes

  • Loose or corroded 2-pin connector on the outlet water temperature probe
  • Failed NTC water temperature sensor (thermistor) on the hot outlet pipe
  • Broken or chafed sensor wire leading back to the main control board
  • Freeze damage to the brass outlet sensor housing

How to Fix Girard Error E4 (Step-by-Step)

0 of 4 steps completed

Recommended Replacement Part for Error E4

If basic checks and resets do not clear E4, verify your exact model sticker and check compatibility for the most commonly replaced part below:

Girard GSWH-2 Outlet Water Temperature Sensor

Reference Part #: 2GWH-23

Disclosure: Links to Amazon may earn RigFaults.com a small commission at no extra cost to you. Always confirm part fitment against your appliance serial number.