Victron RV Solar Charge Controller Error 38: PV Input Shutdown (Over-Voltage Protection Triggered)
Victron Error 38 on RV Solar Charge Controller units (SmartSolar / BlueSolar MPPT 100/30 – 250/100) means PV Input Shutdown (Over-Voltage Protection Triggered). First check: Switch off the solar PV disconnect breaker immediately, then measure open-circuit solar voltage (Voc) with a multimeter to verify it is safely below your MPPT limit (e.g., under 100V for a 100/50). Typical repair cost is $20-$75 DIY / $190+ Shop (Moderate (20-40 mins)).
What Does Victron Error 38 Mean?
On Victron RV Solar Charge Controller systems (SmartSolar / BlueSolar MPPT 100/30 – 250/100), Error 38 indicates PV Input Shutdown (Over-Voltage Protection Triggered). Review the most frequent root causes below before replacing hardware.
Most Common Causes
- Lithium battery BMS cut off charging at 100% SOC, causing a brief battery-side voltage spike
- Solar panel open-circuit voltage (Voc) exceeded controller rating in freezing temperatures
- Another charging source (alternator / shore charger) pushed battery voltage above MPPT over-voltage limit
- Incorrect battery voltage selection (e.g., 12V setting on a 24V battery bank)
How to Fix Victron Error 38 (Step-by-Step)
Recommended Replacement Part for Error 38
If basic checks and resets do not clear Error 38, verify your exact model sticker and check compatibility for the most commonly replaced part below:
Dual-Pole Solar PV DC Disconnect Circuit Breaker (40A-63A)
Disclosure: Links to Amazon may earn RigFaults.com a small commission at no extra cost to you. Always confirm part fitment against your appliance serial number.