Quick Answer

Dometic Error E4 on RV Air Conditioner units (CCC2 / Penguin II Heat Pump / Brisk Air II) means Outdoor Condenser Coil Temperature Sensor Open or Shorted. First check: Turn off both 120V AC and 12V DC power before inspecting the AC unit. Typical repair cost is $20-$45 DIY / $180+ Shop (Moderate (25-45 mins)).

CCC2 / Penguin II Heat Pump / Brisk Air II
Low (Safe to DIY)
Moderate (25-45 mins)
$20-$45 DIY / $180+ Shop

What Does Dometic Error E4 Mean?

On Dometic RV Air Conditioner systems (CCC2 / Penguin II Heat Pump / Brisk Air II), Error E4 indicates Outdoor Condenser Coil Temperature Sensor Open or Shorted. Review the most frequent root causes below before replacing hardware.

Most Common Causes

  • Failed outdoor condenser coil defrost sensor (thermistor)
  • Sensor wire broken or rubbed raw against the metal condenser fan shroud
  • Corroded sensor plug at the upper rooftop control box
  • Incorrect heat pump DIP switch setting on a standard Cool-Only AC board

How to Fix Dometic Error E4 (Step-by-Step)

0 of 4 steps completed

Recommended Replacement Part for Error E4

If basic checks and resets do not clear E4, verify your exact model sticker and check compatibility for the most commonly replaced part below:

Dometic Heat Pump Outdoor Condenser Coil Sensor

Reference Part #: 3310735.005